Cork Store US logo
Cork Store US logo

All articles

What is acceptable moisture content of the subfloor for floating cork flooring?Updated 20 days ago

Requirements for concrete subfloors (after curing a minimum of 30 days for floating floor and 60 days for glue-down flooring):

-Note: a minimum 6 mil polyethylene sheet (vapor barrier) should always be applied under floating floor over below grade. The same vapor barrier is recommended for on-grade applications or over concrete poured within 90 days.

Method 1 (preferred): Less than 75% RH using in-situ probe (ASTM F2170)
Method 2 (second choice): Less than 3 lbs/1,000 sq ft/24 hrs using MVER test (ASTM F1869)
Method 3 (lowest preference): Less than 4.5% using a moisture meter.

For Wood subfloors (plywood/OSB):
6%–9% moisture content (must be within 2% of cork flooring’s moisture content)

Was this article helpful?
Yes